Vial

INDIVIDUAL TEST 900

C3

Indication

Suspicion of complement activation or other deviations within the complement system. Complementary analyzes are often required for the assessment.

Method

Nephelometry

Answer

The result is given as normal, lowered or elevated in g/L

Reference range

Reference range: 0.77-1.38 g/L

Interpretation

C3 and C4 results help to monitor the condition of people with kidney disease (nephritis) or systemic lupus erythematosus (SLE). The results can also help diagnose angioedema, an allergic reaction.

More information

Learn more about sampling.
> Read more

Download request forms

Autoimmune diagnostics

Can't find what you're looking for? We are here to help

Vial

ENSKILD ANALYS 900

C3

Indikation

Vid misstanke om komplementaktivering eller andra avvikelser inom komplementsystemet. Kompletterande analyser krävs ofta för bedömningen.

Metod

Nefelometri

Svar

Resultat anges som normal, sänkt eller förhöjt med g/L

Referensintervall

Referensintervall för vuxna 0.77-1.38 g/L

Tolkning

Resultaten av blodprovet för C3 och C4 hjälper till att övervaka tillståndet hos personer som har njursjukdom (nefrit) eller systemisk lupus erytematosus (SLE). Resultaten kan också hjälpa till att diagnostisera angioödem, en allergisk reaktion.

Mer information

Mer information om provtagning.
> Läs mer

Ladda ner remiss

Autoimmun diagnostik

Hittar du inte vad du söker? Vi kan hjälpa till