DIAGNOSTIC TEST 760
Tr Antibodies (IgG)
Diagnostic test for antibodies against Tr. For suspicion of paraneoplastic syndrome.
Accredited. View certificate [.pdf]
Indication
Suspicion of paraneoplastic syndrome
Sample material
Serum
- Minim. volume: 0,5 mL
CSF
- Minim. volume: 2,0 mL
Transport
Within Sweden
- room temperature
International
- cold
Method
Immunoblot
Reference interval
Serum
- ≤5 negative
CSF
- negative
Result
Serum
- results are reported as negative, borderline, or positive with an intensity value.
CSF
- results are reported as negative, borderline, or positive.
Interpretation
Antibodies against Tr (Trotter antigen, DNER) can be seen in breast or ovarian cancer, small cell lung cancer, thymoma, and Hodgkin's lymphoma and are associated with paraneoplastic encephalomyelitis or cerebellar degeneration.
Antibodies against Tr are graded as High-risk antibodies with a frequency of 90% of underlying cancer and a positive result yields a 3-point PNS score, according to Updated Diagnostic Criteria for Paraneoplastic Neurologic Syndromes.
References
- Rosenfeld MR, Dalmau J. Neurol Clin. 2018. Paraneoplastic Neurologic Syndromes. PMID: 30072076
- Balint B et al. Brain. 2018. Movement disorders with neuronal antibodies: syndromic approach, genetic parallels and pathophysiology. PMID: 29053777
- Graus F et al. Neurol Neuroimmunol Neuroinflamm. 2021. Updated Diagnostic Criteria for Paraneoplastic Neurologic Syndromes. PMID: 34006622
- Garza M, Piquet AL. Front Neurol. 2021. Update in Autoimmune Movement Disorders: Newly Described Antigen Targets in Autoimmune and Paraneoplastic Cerebellar Ataxia. PMID: 34489848
Included in these panels
Need pricing information?
How to order
This test is available worldwide for hospitals, clinics, and physicians.
-
Print and complete the request form
Download the request form. Clearly state the name and phone number of the referring hospital, clinic, or physician. -
Prepare your samples
Serum: At least 0.5 mL serum (plain serum tubes without additives).
CSF: At least 2 mL CSF (polypropylene tubes).
-
Send samples and request form
Within Sweden
Samples can be sent at room temperature to:
Envelopes and smaller boxes:
Wieslab AB, Box 50117, 20211 Malmö, Sweden
Larger boxes and frozen samples:
Wieslab AB, Lundavägen 151, 21224 Malmö, Sweden
International
Send samples cold to:
Wieslab AB, Lundavägen 151, 21224 Malmö, Sweden
Last updated: 2025-08-18