INDIVIDUAL TEST 926

C1 INH Function

Indication

Investigation of angioedema 

Method

The analysis is performed on plasma with spectrophotometry. 

Result

The result is reported as a percentage of normal human serum and as normal or reduced. Reference interval: 72-129 %. 

Interpretation

Results below the lower reference limit may indicate hereditary angioedema (HAE) type 1 or consumption of C1-inhibitor (can be seen in some malignancies). The result should primarily be verified with a new sample as well as to include analysis of concentration of C1-inhibitor and C4  

References

Li HH et al; COMPACT Investigators. Subcutaneous C1 inhibitor for prevention of attacks of hereditary angioedema: additional outcomes and subgroup analysis of a placebo-controlled randomized study. Allergy Asthma Clin Immunol. 2019 15:49. PMID: 31485239. 

More information

Learn more about sampling.
> Read more

Download request forms

Autoimmune diagnostics

Can't find what you're looking for? We are here to help

Vial

ENSKILD ANALYS 926

C1-INH funktion

Indikation

Vid utredning av angioödem 

Metod

Analysen utförs på plasma med spektrofotometri. 

Svar

Resultatet anges som procent av normalt humanserum och som normalt eller sänkt. Referensintervall: 72-129%. 

Tolkning

Resultat under nedre referensgränsen kan tyda på hereditärt angioödem (HAE) typ 1 eller konsumtion av C1-inhibitor (kan ses vid vissa maligniteter). Resultatet bör i första hand verifieras med nytt prov för verifiering och även inkludera analys av koncentration av C1-inhibitor och C4 

Referenser

Li HH et al; COMPACT Investigators. Subcutaneous C1 inhibitor for prevention of attacks of hereditary angioedema: additional outcomes and subgroup analysis of a placebo-controlled randomized study. Allergy Asthma Clin Immunol. 2019 15:49. PMID: 31485239.

Mer information

Mer information om provtagning.
> Läs mer

Ladda ner remiss

Autoimmun diagnostik

Hittar du inte vad du söker? Vi kan hjälpa till