DIAGNOSTIC TEST 970
Trib2 Antibodies
Diagnostic test for antibodies against Trib2. For suspicion of narcolepsy.
Indication
Suspicion of narcolepsy
Sample material
Serum
- Minim. volume: 0,5 mL
Transport
- Within Sweden: room temperature
- International: cold
Method
Radioimmunoprecipitation (RIP)
Reference interval
<10 negative, 10-15 borderline
Result
Results are reported as negative, borderline, or positive with a titer.
Interpretation
Antibodies against Trib-2 have been reported in up to 26 % of patients with narcolepsy and cataplexy, but the diagnosis is primary based on clinical symptoms, HLA-typing and hypocretin levels in CSF.
References
- Cvetkovic-Lopes V et al. J Clin Invest. 2010. Elevated Tribbles homolog 2-specific antibody levels in narcolepsy patients. PMID: 20160349
- Kawashima M et al. Sleep. 2010. Anti-Tribbles homolog 2 (TRIB2) autoantibodies in narcolepsy are Associated with Recent Onset of cataplexy. PMID: 20614846
- Toyoda H et al. Sleep. 2010. Anti-Tribbles homolog 2 autoantibodies in Japanese patient with narcolepsy. PMID: 20614847
- Winding A et al. J Autoimmun. 2014. A/H1N1 Antibodies and TRIB2 autoantibodies in narcolepsy patient Diagnosed in Conjunction with the Pandemrix vaccination campaign in Sweden 2009-2010. PMID: 24485154
- Zhang Y et al. Mol Immunol. 2005. Identification of tribbles homolog 2 as an autoantigen in autoimmune uveitis by phage display. PMID: 15950723
Need pricing information?
How to order
This test is available worldwide for hospitals, clinics, and physicians.
-
Print and complete the request form
Download the request form. Clearly state the name and phone number of the referring hospital, clinic, or physician. -
Prepare your samples
Serum: At least 0.5 mL serum (plain serum tubes without additives).
-
Send samples and request form
Within Sweden
Samples can be sent at room temperature to:
Envelopes and smaller boxes:
Wieslab AB, Box 50117, 20211 Malmö, Sweden
Larger boxes and frozen samples:
Wieslab AB, Lundavägen 151, 21224 Malmö, Sweden
International
Send samples cold to:
Wieslab AB, Lundavägen 151, 21224 Malmö, Sweden
Last updated: 2025-12-05