DIAGNOSTIC TEST 805
Plexin D1 Antibodies (IgG)
Diagnostic test for antibodies against Plexin D1. For suspicion of small fiber neuropathy.
Indication
Suspicion of small fiber neuropathy (SFN)
Sample material
Serum
- Minim. volume: 0,5 mL
Transport
- Within Sweden: room temperature
- International: cold
Method
Western Blot
Reference interval
Negative
Result
Results are reported as negative, borderline, or positive.
Interpretation
Antibodies against Plexin D1 can be detected in polyneuropathy patients with sensory polyneuropathy, which is often characterized as burning pain and thermal hyperalgesia.
References
- Fujii T et al. Ann Neurol. 2018. A Novel Autoantibody against Plexin D1 in Patients with Neuropathic Pain. PMID: 30014510
- Fujii T et al. Neurol Neuroimmunol Neuroinflamm. 2020. Painful trigeminal neuropathy associated with anti-Plexin D1 antibody. PMID: 32587101
- Zeidman LA. Neurol Clin. 2021. Advances in the Management of Small Fiber Neuropathy. PMID: 33223078
- Morelli L et al. Rev Neurosci. 2024. The role of antibodies in small fiber neuropathy: a review of currently available evidence. PMID: 38865989
Included in these panels
Need pricing information?
How to order
This test is available worldwide for hospitals, clinics, and physicians.
-
Print and complete the request form
Download the request form. Clearly state the name and phone number of the referring hospital, clinic, or physician. -
Prepare your samples
Serum: At least 0.5 mL serum (plain serum tubes without additives).
-
Send samples and request form
Within Sweden
Samples can be sent at room temperature to:
Envelopes and smaller boxes:
Wieslab AB, Box 50117, 20211 Malmö, Sweden
Larger boxes and frozen samples:
Wieslab AB, Lundavägen 151, 21224 Malmö, Sweden
International
Send samples cold to:
Wieslab AB, Lundavägen 151, 21224 Malmö, Sweden
Last updated: 2025-12-05