DIAGNOSTIC TEST 027
SSA/Ro60 Antibodies
Diagnostic test for antibodies against SSA. For suspicion of Sjögren's syndrome and systemic lupus erythematosus.
Indication
Suspicion of Sjögren's syndrome and systemic lupus erythematosus
Sample material
Serum
- Minim. volume: 0,5 mL
Transport
Within Sweden
- room temperature
International
- cold
Method
Immunoblot
Reference interval
- ≤10 negative
Result
Results are reported as negative or positive with an intensity value.
Interpretation
Anti-SSA/Ro60 antibodies occur mainly in Sjögren's syndrome and systemic lupus erythematosus but can also be seen in other rheumatic systemic diseases and are associated with small fiber neuropathy. During pregnancy, anti-SSA is associated with neonatal lupus.
Referenser
- Tomer Y et al. Int Arch Allergy Immunol. 1993. Pathogenic significance and diagnostic value of lupus autoantibodies. PMID: 8481649
- von Mühlen CA, Tan EM. Semin Arthritis Rheum. 1995. Autoantibodies in the diagnosis of systemic rheumatic diseases. PMID: 7604300
- Van Duijnhoven HL et al. Clin Biochem. 1999. A comparison of ELISA assays as routine diagnostic test for detection of autoantibodies against extractable nuclear antigens. PMID: 10383077
- Hiepe F et al. Int Arch Allergy Immunol. 2000. Antinuclear antibody- and extractable nuclear antigen-related diseases. PMID: 11014966
- Mahler M et al. Clin Immunol. 2003. Advances in B-cell epitope analysis of autoantigens in connective tissue diseases. PMID: 12763475
- Hennes EM et al. Hepatology. 2008. Simplified criteria for the diagnosis of autoimmune hepatitis. PMID: 18537184
- Damoiseaux J et al. Ann Rheum Dis. 2019. Clinical relevance of HEp-2 indirect immunofluorescent patterns: the International Consensus on ANA patterns (ICAP) perspective. PMID: 30862649
Included in these panels
Need pricing information?
How to order
This test is available worldwide for hospitals, clinics, and physicians.
-
Print and complete the request form
Download the request form. Clearly state the name and phone number of the referring hospital, clinic, or physician. -
Prepare your samples
Serum: At least 0.5 mL serum (plain serum tubes without additives).
-
Send samples and request form
Within Sweden
Samples can be sent at room temperature to:
Envelopes and smaller boxes:
Wieslab AB, Box 50117, 20211 Malmö, Sweden
Larger boxes and frozen samples:
Wieslab AB, Lundavägen 151, 21224 Malmö, Sweden
International
Samples can be sent at room temperature to:
Wieslab AB, Lundavägen 151, 21224 Malmö, Sweden
Last updated: 2025-08-18