Vial

INDIVIDUAL TEST 965

Titin Antibodies (IgG)

Indication

Suspicion of Myastenia Gravis or paraneoplastic syndrome

Sample material

Serum

  • Minim. volume: 0,5 mL

CSF

  • Minim. volume: 2,0 mL

Transport

Within Sweden

  • room temperature

International

  • cold

Method

Immunoblot

Reference interval

Serum

  • ≤5 negative

CSF

  • negative

Result

Serum

  • results are reported as negative, borderline, or positive with an intensity value.

CSF

  • results are reported as negative, or positive.

Interpretation

Antibodies against Titin can be detected in patients with Myasthenia Gravis and are associated with thymoma.

References

  • Rosenfeld MR, Dalmau J. Neurol Clin. 2018. Paraneoplastic Neurologic Syndromes. PMID: 30072076
  • Balint B et al. Brain. 2018. Movement disorders with neuronal antibodies: syndromic approach, genetic parallels and pathophysiology. PMID: 29053777
  • Graus F et al. Neurol Neuroimmunol Neuroinflamm. 2021. Updated Diagnostic Criteria for Paraneoplastic Neurologic Syndromes. PMID: 34006622
  • Garza M, Piquet AL. Front Neurol. 2021. Update in Autoimmune Movement Disorders: Newly Described Antigen Targets in Autoimmune and Paraneoplastic Cerebellar Ataxia. PMID: 34489848
  • Sanders D.B et al. Neurology. 2016. International consensus guidance for management of myasthenia gravis. PMID: 27358333

Last updated: 2024-10-22

More information

This is an accredited test.
> Read more [.pdf]

Learn more about sampling.
> Read more

Download request forms

Neurology

Can't find what you're looking for? We are here to help

Vial

ENSKILD ANALYS 965

Titin-antikroppar (IgG)

Indikation

Misstanke om Myastenia Gravis eller paraneoplastiskt syndrom

Provmaterial

Serum

  • Minim. volym: 0,5 mL

Likvor

  • Minim. volym: 2,0 mL

Transport

Inom Sverige

  • rumstemperatur

Internationellt

  • kylt

Metod

Immunoblot

Referensintervall

Serum

  • ≤5 negativt

Likvor

  • negativt

Resultat

Serum

  • resultat anges som negativt, gränsvärde eller positivt med intensitetsvärde.

Likvor

  • resultat anges som negativteller positivt.

Tolkning

Antikroppar mot Titin kan påvisas hos patienter med Myastenia Gravis och är associerat med tymom.

Referenser

  • Rosenfeld MR, Dalmau J. Neurol Clin. 2018. Paraneoplastic Neurologic Syndromes. PMID: 30072076
  • Balint B et al. Brain. 2018. Movement disorders with neuronal antibodies: syndromic approach, genetic parallels and pathophysiology. PMID: 29053777
  • Graus F et al. Neurol Neuroimmunol Neuroinflamm. 2021. Updated Diagnostic Criteria for Paraneoplastic Neurologic Syndromes. PMID: 34006622
  • Garza M, Piquet AL. Front Neurol. 2021. Update in Autoimmune Movement Disorders: Newly Described Antigen Targets in Autoimmune and Paraneoplastic Cerebellar Ataxia. PMID: 34489848
  • Sanders D.B et al. Neurology. 2016. International consensus guidance for management of myasthenia gravis. PMID: 27358333

Senast uppdaterat: 2024-10-22

Mer information

Detta är en ackrediterad analys.
> Läs mer [.pdf]

Mer information om provtagning.
> Läs mer

Ladda ner remiss

Neurologi

Hittar du inte vad du söker? Vi kan hjälpa till